  • EOP-011-4 - North American Electric Reliability Corporation
    This Attachment provides the process and descriptions of the levels used by the Reliability Coordinator in which it communicates the condition of a Balancing Authority which is experiencing an Energy Emergency
  • EOP-011-4 – Emergency Operations - NERCipedia
    An Energy Emergency Alert (EEA) may be initiated only by a Reliability Coordinator at 1) the Reliability Coordinator ’s own request, or 2) upon the request of an energy deficient Balancing Authority
  • Best Practices for Energy Emergency Alerts
    A BA can be placed into one of three EEA levels based on the severity of the event, where level 1 is the least severe, and level 3 is the most severe An EEA, however, is something that should not be used as a daily operating practice
  • ERCOT’s use of Energy Emergency Aler
    When operating reserves drop below 2,300 MW and are not expected to recover within 30 minutes, grid operators can call on all available power supplies, including power from other grids, if available
  • PJM’s Emergency Procedures and Messages
    A Voltage Reduction Alert and public appeal for electricity conservation falls within a NERC EEA Level 2, or EEA-2 NERC defines an EEA-2 as when a grid operator is no longer able to provide its expected energy requirements, but is still able to maintain minimum contingency reserve requirements
  • E-3 Docket Nos. RM15-7-000, RM15-12-000, and RM15-13-000
    A company-specific system restoration plan that includes an Operating Procedure for black-starting units, Operating Processes for communicating restoration progress with other entities, etc , is an example of an Operating Plan ”
  • RSG Operating Process - Spp
    Operating Reserves are needed to regulate load changes and to support an Operating Reserve Contingency without shedding firm load or curtailing Firm Power Sales
  • BAL-002-WECC-3 - North American Electric Reliability Corporation
    The amount of Contingency Reserve equal to the loss of the most severe single contingency; The amount of Contingency Reserve equal to the sum of three percent of hourly integrated Load plus three percent of hourly integrated generation
  • Template - Standard (Results Based)
    The EOP SDT modified the “Circumstances” for EEA 2 to show that an entity will be in this level when it has implemented its Operating Plan(s) to mitigate Emergencies but is still able to maintain Contingency Reserves